Heat transfer fluids play a critical role in industrial heating systems, efficiently transferring thermal energy to process equipment across applications such as chemical processing, food manufacturing, asphalt production and paper manufacturing.
Operating at high temperatures can place significant stress on heat transfer oils, making thermal stability and resistance to fluid degradation essential for reliable performance. Mobil™ heat transfer fluids are designed to deliver efficient heat transfer, long fluid life and dependable operation in demanding industrial environments.
Lubricants for heat transfer
-
Mobiltherm™ FM 32
For heat transfer systems requiring NSF H1-registered, Halal- and Kosher-certified lubricants. Suitable for high-temperature heat transfer applications with maximum bulk operating temperatures up to 300 °C and maximum film temperatures up to 315 °C. For food and beverage processing applications where incidental food contact may occur.
-
Mobil SHC Cibus™ 32 HT
Fully synthetic heat transfer oil intended for use in closed, indirect heating installations where NSF H1 registered lubricants are required.
-
Mobiltherm™ 600 Series
Heat transfer oils for use in cold-oil sealed, indirect heating and cooling systems in all kinds of industrial processes.
Services that help optimise heat transfer system performance
Heat transfer fluid performance depends on more than selecting the right lubricant. Operating conditions such as temperature, flow rate, oxidation and system cleanliness can all affect fluid life and heat transfer efficiency. Mobil℠ Services supports heat transfer system operators with technical expertise, fluid condition monitoring and maintenance guidance to help identify degradation, reduce deposit formation and maintain reliable system performance.
Frequently asked questions
A heat transfer fluid is a specially formulated oil used to transfer thermal energy in indirect heating and cooling systems. It circulates between a heater and process equipment, carrying heat efficiently throughout the system while helping maintain consistent operating temperatures.
Heat transfer fluids are commonly used in:
- Chemical processing
- Food manufacturing
- Asphalt production
- Paper manufacturing
- Plastics processing
- Petroleum and gas processing
The performance of the heat transfer fluid can have a significant impact on system efficiency, equipment reliability and maintenance requirements.
Heat transfer fluids are exposed to demanding operating conditions and naturally age over time. The most common causes of degradation include:
- Excessive temperatures that can lead to thermal cracking
- Poor circulation causing localized hot spots
- Oxidation from exposure to air
- Contamination from water or process materials
As degradation progresses, operators may experience reduced heat transfer efficiency, deposit formation, increased maintenance requirements and shorter fluid life. Monitoring operating conditions and fluid condition can help identify issues before they impact performance.
Proper circulation is one of the most important factors in maintaining heat transfer system performance.
Adequate flow helps:
- Transfer heat more efficiently
- Control film temperature at heater surfaces
- Minimize localized overheating
- Reduce deposit formation
- Support longer fluid life
Poor flow or stagnant zones can increase film temperatures and accelerate thermal degradation. Maintaining sufficient circulation throughout the system helps protect both the fluid and the equipment.
A simple principle applies to every heat transfer system: flow helps protect the oil.
Film temperature is the temperature of the thin layer of fluid that is in direct contact with the heater surface. It is typically higher than the bulk fluid temperature circulating through the system.
Film temperature is often the most critical factor affecting fluid life because excessive temperatures at the heater surface can accelerate degradation and lead to:
- Thermal cracking
- Carbon deposits
- Reduced heat transfer efficiency
- Increased maintenance requirements
For this reason, maintaining proper circulation and operating within recommended temperature limits is essential for reliable system performance.
Several indicators may suggest that a heat transfer fluid should be evaluated.
Common warning signs include:
- Reduced heat transfer performance
- Rising operating temperatures
- Increasing pressure drop
- Frequent filter blockage
- Pump noise or cavitation
- Darkened fluid appearance
- Increased fouling or deposits
If these symptoms are observed, reviewing operating conditions and performing fluid analysis can help determine the cause and identify appropriate corrective actions.
Maintaining proper operating conditions is essential for helping maximize heat transfer fluid life, system efficiency and equipment reliability.
Best practices include:
- Maintaining adequate fluid circulation at all times
- Keeping filters clean and functioning properly
- Monitoring operating temperatures regularly
- Maintaining turbulent flow where possible to improve heat transfer
- Starting fluid circulation before energizing the heater
- Continuing circulation during system cool-down
- Conducting regular fluid condition monitoring and analysis to identify potential issues early
Operators should avoid:
- Running a heater without adequate fluid flow
- Stopping circulation while the heater remains hot
- Exceeding recommended operating temperatures
- Ignoring deposits, fouling or frequent filter blockages
- Allowing stagnant zones to develop within the system
Regular fluid analysis can provide valuable insight into both fluid condition and overall system health. Testing may help identify degradation, oxidation, contamination and other changes before they affect operation.
Benefits can include:
- Earlier identification of potential issues
- More informed maintenance decisions
- Improved system reliability
- Better understanding of fluid condition
- Support for maximizing fluid service life
In addition to lubricant technology, Mobil™ provides technical expertise and services that can help customers monitor fluid condition, troubleshoot operating issues and support heat transfer system performance.